2023-01-18 23:39:46 +08:00
;
; Answering Machine Detection Configuration
;
[general]
initial_silence = 2500 ; Maximum silence duration before the greeting.
; If exceeded then MACHINE.
greeting = 1500 ; Maximum length of a greeting. If exceeded then MACHINE.
after_greeting_silence = 800 ; Silence after detecting a greeting.
; If exceeded then HUMAN
total_analysis_time = 5000 ; Maximum time allowed for the algorithm to decide
; on a HUMAN or MACHINE
min_word_length = 100 ; Minimum duration of Voice to considered as a word
between_words_silence = 50 ; Minimum duration of silence after a word to consider
; the audio what follows as a new word
maximum_number_of_words = 3 ; Maximum number of words in the greeting.
; If exceeded then MACHINE
silence_threshold = 256