system.conf.sample: Add note regarding cross connecting spans on B410P.
There is an issue with the hardware on the B410P that makes it unreliable to connect one of the ports to another port for testing. Signed-off-by: Shaun Ruffell <sruffell@digium.com> git-svn-id: http://svn.astersk.org/svn/dahdi/tools/trunk@10026 17933a7a-c749-41c5-a318-cba88f637d49
This commit is contained in:
parent
9ae57618d3
commit
52b37fa5f1
@ -32,6 +32,12 @@
|
||||
# Incorrect timing sync may cause clicks/noise in the audio, poor quality or failed
|
||||
# faxes, unreliable modem operation, and is a general all round bad thing.
|
||||
#
|
||||
# NOTE: The B410P card cannot reliably connect one of its four ports
|
||||
# configured in TE mode to another one configured in NT mode. It will not
|
||||
# reliably sync clock from itself. Please use another physical card and
|
||||
# configure one to provide clock and one to recover clock in any B410P test
|
||||
# environments.
|
||||
#
|
||||
# The line build-out (or LBO) is an integer, from the following table:
|
||||
#
|
||||
# 0: 0 db (CSU) / 0-133 feet (DSX-1)
|
||||
|